您现在的位置是:网站首页>行业标准Q/GDW 11086-2013 变电设备不拆高压引线试验导则

Q/GDW 11086-2013 变电设备不拆高压引线试验导则

简介
Q/GDW 11086-2013
变电设备不拆高压引线试验导则
The guide for the test of Transformation Equipment without removing the high-voltage lead
2014-09-01实施
2014-09-01发布
目 次
前言................................................................................1
1范围............................................................................1
2 规范性引用文件.....................................................................1
3术语和定义.........................................................................1
4总则...........................................................................1
5试验方法.........................................................................1
5.1油浸式电力变压器和电抗器....................................................1
5.2电容型套管..............................................5
5.3隔离开关..............................................................6
5.4断路器 ................................................7
5.5油浸式电流互感器...........................................................9
5.6耦合电容器 .................................................10
5.7电容式电压互感器.............................................................14
5.8电磁式电压互感器...............................................................18
5.9金属氧化物避雷器...............................................................19
5.10 并联电容器...................................................................22 
前 言
为规范变电设备不拆高压引线试验的现场应用,提升设备停电例行试验效率,减少检修工作量,提高变电设备的运行可靠性,制定本标准。
本标准由国家电网公司运维检修部提出并解释。
本标准由国家电网公司科技部归口。
1 范围
本标准规定了变电设备不拆高压引线试验时的现场条件、试验接线、注意事项以及试验数据分析原则等。
本标准适用于 110~1000kV 变压器(高压并联电抗器)、电容型套管、隔离开关、断路器、油浸式电流互感器、耦合电容器、电容式电压互感器、电磁式电压互感器、金属氧化物避雷器和 35kV 及以下并联电容器等变电设备的不拆高压引线试验工作。
2 规范性引用文件
下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。